How to Use the doseBadge Noise Dosimeter

The doseBadge Noise Dosimeter Kits include all the parts that you need to carry out the following processes:

Start of the Working Day using the dosebadge noise dosimeter
 
  1. Fit the doseBadge onto the Reader and press the Reset key to clear its memory
  2. Calibrate the doseBadge by pressing the Cal key
  3. Attach the doseBadge to the worker using the supplied fixing
  4. Point the Reader at the doseBadge and press the Run key
 

Leave the doseBadge measuring for the full working shift...

 
End of the Working Day
 
  1. Point the Reader at the doseBadge and press the Stop key
  2. Remove the doseBadge from the worker and fit it onto the Reader
  3. Press the Cal key if you want a second calibration
  4. Press Read to transfer the results to the Reader
  5. Put the doseBadge on to charge

The measurements can be viewed on the Reader's built in graphic screen or they can be transferred to a computer for storage, analysis and reporting. The Reader can download a number of doseBadges before the measurements are transferred to a computer, so it is only necessary to carry the Reader on site.

 

 