| Standards |
ANSI S1.4 Type 2
IEC 60651:1979 Type 2 |
| Measurement Range |
"A" Weighted : 35dB(A) to 130dB(A)
"C" Weighted : 40dB(C) to 130dB(C) |
| Range Selection |
L (Low) = 35dB(A) to 100dB(A)
H (High) = 65dB(A) to 130dB(A) |
| Frequency Weighting |
"A" and "C" Weighting - dB(A) & dB(C) |
| Time Weighting |
P14: Fast - "F"
P14S: Slow - "S" |
| Display Functions |
Normal (Sound Level), Maximum Hold |
| Measurement Functions |
LAF- Fast, "A" Weighted Sound Level (P14)
LCF - Fast, "C" Weighted Sound Level (P14)
LAS- Slow, "A" Weighted Sound Level (P14S)
LCS - Slow, "C" Weighted Sound Level (P14S)
LAMax - Maximum "A" Weighted Sound Level
LCMax - Maximum "C" Weighted Sound Level |
| Display Flags |
Overload (Green Light), Under range (Red Light)
Maximum Hold (HOLD), Low battery (LOWBAT) |
| Display |
3 ½ digit LCD with 0,1dB Resolution |
| Outputs |
AC Out Max output = 2V |
| Power |
1 x 9V (6F22, PP3), External DC Power, 7V to 10V |
| Microphone |
½” pre-polarised electret condenser |
| Temperature |
Operating: 14°F to 122°F, Storage: -4°F
to 140°F
Operating: -10°C to +50°C, Storage: -20°C
to +60°C |
| Dimensions |
9.7" x 2.6" x 1.2" (248 x 66 x 30 mm)
Weight 8oz (227 gms) with battery |
| CE classification |
EMC : EN50081-1, EN 50082-1
Safety : EN 61010-1, 1993 portable equipment pollution
category 2 |